CANADIAN LEATHER GLOVES
Split leather gloves with knuckle protection.
KEY FEATURES
Split leather gloves.
Five finger interlining.
Dyed cotton back.
Canvas cuff/rubberized cuff.
DESIGN:
Canadian assembly.
Elasticated wrist.
PRODUCT MAKE :
Material : Split leather
Cuff : Canvas/Rubber
Lining : Five finger interlining
Piping : None
SIZE: Universal 6 7 8 9 10 11
INDUSTRY / JOB: Manufacturing, Material Handling, Construction & Civil, Iron & Steel, Repairs & Maintenance, Agriculture, Forestry & Horticulture, Warehousing & Assembling
HAZARD / RISK: Abrasion, Puncture, Friction, Impact, Vibration, Heat
PRODUCT WEIGHT: 2196 gms per dozen pair
( Weight of product may vary depending on customisations )
MINIMUM ORDER QUANTITY :
Custom : 10000 Pair
Ready Made : 120 Pairs
Instructions for storage: Store in a cool, dry place; away from frost and light in their original packaging.
Warning: Gloves not to be worn when there is a risk of entanglement by moving parts of machines.
Abrasion as per EN 388 is 3: Resistance to abrasion based on the number of cycles required to abrade through the sample glove (abrasion by sandpaper under a stipulated pressure). The protection factor is then indicated on a scale from 1 to 4 depending on how many revolutions are required to make a hole in the material. The higher the number, the better the glove.
Cut as per EN 388 is 1: Blade cut resistance based on the number of cycles required to cut through the sample at a constant speed. The protection factor is then indicated on a scale from 1 to 5.
Tear as per EN 388 is 3: Tear resistances based on the amount of force required to tear the sample. The protection factor is then indicated on a scale from 1 to 4.
Puncture as per EN 388 is 2: Puncture resistances based on the amount of force required to pierce the sample with a standardly sized point. The protection factor is then indicated on a scale from 1 to 4.
TDM blade cut resistant as per EN 388 is X (X means not tested): The glove sample is placed on a conductive strip and loaded onto the TDM-100. When the metal blade touches the metal strip, the test is terminated. A straight blade is loaded into the machine. Weight is added to serve as a force. The blade moves across the fabric. The blade is replaced with a new one to ensure accuracy. The sample is cut five times, each with three different loads. The distance traveled to cause cut through at various forces is recorded. The data is used to determine the load required to cut through the sample.
This glove does not contain a substance known as being carcinogenic, neither toxic nor likely to cause allergies to sensitive people.
It is generally recommended that leather gloves be dry cleaned. Soap and water remove the natural oils present in the leather, causing them to stiffen and become brittle.
The leather used in the manufacture of this glove has chrome and PH within permissible limits.
Easy to wear and remove the gloves.